Features

Utilization of testing and measuring instruments like DC Power Supply, Digital Multimeter, Signal Generator, Digital Storage Oscilloscope are highly emphasized in these training systems.

 

Experiments Modules

TC-3000-01 Second Order Active Filters and RF Oscillators Experiments Module
Lab 1 Second Order Active Filters
Experiment 1 Second Order Active Low-pass Filter (Low-pass -3dB Frequency: 1 kHz ~ 3 kHz)
Experiment 2 Second Order Active High-pass Filter (High-pass -3 dB Frequency: 5 kHz ~ 10 kHz)
Experiment 3 Second Order Active Band-pass Filter (Center Frequency:10 kHz ~ 100 kHz, Bandwidth: (6 kHz ~ 60 kHz)
Experiment 4 Second Order Active Band-stop Filter (Cutoff Frequency: 10 kHz ~ 100 kHz, Bandwidth:6 kHz ~ 60 kHz)
Lab 2 RF Oscillators
Experiment 1 Colpitts Oscillator (Oscillation Frequency: 1 MHz ~ 9 MHz)
Experiment 2 Hartley Oscillator (Oscillation Frequency: 500 kHz ~ 1.8 MHz)
Experiment 3 Crystal Oscillator (Oscillation Frequency: 500 kHz ~ 1.8 MHz)
Experiment 4 Voltage Controlled Oscillator (Oscillation Frequency: 3.5 MHz ~ 4 MHz)
 

TC-3000-02 AM Modulator and Demodulator Experiments Module
Lab 3 AM Modulator
Experiment 1 Transistor AM Modulator (Carrier Signal: 1.5 kHz ~ 2 kHz, Audio Signal: 500 Hz ~ 1 kHz)
Experiment 2 MC1496 AM Modulator (Carrier Signal: 500 kHz ~ 1 MHz, Audio Signal: 500 Hz ~ 1 kHz)
Lab 4 AM Demodulator
Experiment 1 AM Diode Detector (Carrier Signal:300 kHz, Audio Signal: 500 Hz ~ 2 kHz)
Experiment 2 AM Product Detector (Carrier Signal: 500 kHz ~ 1 MHz, Audio Signal: 500 Hz ~ 1 kHz)
TC-3000-03 DSB-SC and SSB Modulator and Demodulator Experiments Module
Lab 5 DSB-SC and SSB Modulator
Experiment 1 DSB-SC Modulator (Carrier Signal: 100 kHz ~ 500 kHz, Audio Signal: 500 Hz ~ 1 kHz)
Experiment 2 SSB Modulator (Carrier Signal: 200 kHz, Audio Signal: 500 Hz ~ 1 kHz)
Lab 6 DSB-SC and SSB Demodulator
Experiment 1 DSB-SC Product Detector (Carrier Signal: 100 kHz ~ 500 kHz, Audio Signal: 500 Hz ~ 1 kHz)
Experiment 2 SSB Product Detector (Carrier Signal: 200 kHz, Audio Signal: 500 Hz ~ 1 kHz)

 

TC-3000-04 FM Modulator and Demodulator Experiments Module
Lab 7 FM Modulator
Experiment 1 MC4046 FM Modulator (Carrier Signal: 20 kHz, Audio Signal: 1 kHz)
Experiment 2 LM566 FM Modulator (Carrier Signal: 20 kHz, Audio Signal: 500 Hz ~ 700 Hz)
Lab 8 FM Demodulator
Experiment 1 MC4046 FM Demodulator (Carrier Signal: 20 kHz, Audio Signal: 1 kHz)
Experiment 2 LM565 FM Demodulator (Carrier Signal: 20 kHz, Audio Signal: 500 Hz ~ 700 Hz)

 

TC-3000-05 TDM Multiplexer and Demultiplexer Experiments Module
Lab 9 TDM Multiplexer
Experiment 1 Waveform Generator (Sine Wave Signal Generator: 13 kHz, Triangle Wave Signal Generator: 2.3 kHz, Square Wave Signal Generator: 2.3 kHz)
Experiment 2 TDM Multiplexer (Transmission Channels: 3 Channels, Switching Time:500 ms ~ 50 ms)
Lab 10 TDM Demultiplexer
Experiment 1 TDM Demultiplexer (Transmission Channels: 3 Channels, Switching Time:500 ms ~ 50 ms)

 

TC-3000-06 FDM Multiplexer and Demultiplexer Experiments Module
Lab 11 FDM Multiplexer
Experiment 1 FDM Signal Generator (Carrier Signal: 500 kHz ~ 1.5 MHz, Audio Signal: 500 Hz ~ 1.5 kHz)
Experiment 2 DSB-SC Modulated Signal Generator (Carrier Signal: 500 kHz ~ 1.5 MHz, Audio Signal: 500 Hz ~ 1.5 kHz)
Experiment 3 FDM Multiplexer (Modulation Type: DSB-SC Signal, Transmission Bandwidth: 2 MHz)
Lab 12 FDM Demultiplexer
Experiment 1 FDM Demultiplexer (Modulation Type: DSB-SC Signal, Demultiplexing Type: Product Demultiplexer)

 

TC-3000-07 A/D & D/A Converter Experiments Module
Lab 13 Analog-to-Digital Converter
Experiment 1 ADC0804 Analog-to-digital Converter (Resolution: 8 bits, Analog Input Voltage: 0 V ~ 5 V)
Experiment 2 ADC0809 Analog-to-digital Converter (Resolution: 8 bits, Analog Input Voltage: 0 V ~ 5 V,
Lab 14 Digital-to-Analog Converter
Experiment 1 R-2R Digital-to-analog Converter (Digital Input: 4 bits, Analog Output: 0 V ~ 5 V)
Experiment 2 Unipolar DAC 0800 Digital-to-analog Converter (Digital Input: 8 bits, Analog Output: 0 V ~ 5 V, Step Value: 0.019 V)
Experiment 3 Bipolar DAC 0800 Digital-to-analog Converter (Digital Input: 8 bits, Analog Output: -5 V ~ 5 V, Step Value: 0.038 V)

 

TC-3000-08 Frequency Converter and Signal Recovery Experiments Module
Lab 15 Frequency Converter
Experiment 1 Frequency Multiplier (Carrier Signal: 10 kHz)
Experiment 2 Up/Down Frequency Converter (Carrier Signal @ LO port: 100 kHz; Carrier Signal @ RF port: 120 kHz)
Lab 16 Signal Recovery
Experiment 1 Carrier Signal Recovery Circuit (Carrier Signal: 10 kHz)
Experiment 2 Clock Recovery Circuit (Clock Signal: TTL, Encoded Signal: Manchester, Clock Frequency: 5 kHz ~ 10 kHz)

 

Accessory Sets

 

TC-3000-TS2 2mm Stackable Test Lead Set (350mm Length)
Assorting in 5 different colors 25 units : Red x 5, Yellow x 5, Blue x 5, Black x 5, Green x 5
TC-3000-TS4 4mm Stackable Test Lead Set (350mm Length)
Assorting in 5 different colors 10 units : Red x 2, Yellow x 2, Blue x 2, Black x 2, Green x 2
 

Universal Lab Station ULS-2000

 

DC Power Supply
Fixed Output: +5V/0.5A, -5V/0.5A, +12V/0.5A, -12V/0.5A
Variable Output: +0V ~ +23V/1A, -0V ~ -23V/1A
AC Power Supply
Fixed Output: 19V–15V–9V–0V–9V–15V-19V
Function Generator
Sine, Triangle and Square waveform output
Frequency range: 1Hz to 1MHz in 6 decades
With fine adjust, Amplitude and DC offset control
TTL Mode Output Range: 1Hz to 1MHz in 6 decades
Six frequency ranges:

 

 

1Hz to 10Hz
10Hz to 100Hz
100Hz to 1KHz
1KHz to 10KHz
10KHz to 100KHz
100KHz to 500KHz
Sine wave output: 0 to 12V peak to peak variable
Triangle wave output: 0 to 8V peak to peak variable
Square wave output: 0 to 16V peak to peak variable
Five (5) Data Switches Module
5 units slide switches and corresponding output terminals. When switch is set at “down” position, the output is LO level; contrarily, it is to be HI level when setting at “up” position.
Multi Interface Adaptor Module
Miniature Socket, 2mm Socket & 4mm Banana Adaptors

 

Optional Equipment Need To Complete The Experiments Testing

 

1.0 3 ½ Digits Digital Multimeter
2.0 60MHz Digital Storage Oscilloscope

 

Note: Specification, Layout, Design etc. May Change Without Prior Notice For Products Continuous Development Process.