Power Factor Correction Training Panel Complete With RLC Loading Units EM-600309Description
- Description
Description
The unit is specially developed for use in electrical teaching laboratory for the purposed of demonstrating the basic concept and the operating principle of power factor correction system.
FEATURES
- All Required components are systematically and didactically arranged on a sloping study panel with all internal components and circuit schematically represented by screen-printed mimic diagrams.
- Actual industrials system but specially adapted for teaching and demonstration purposes.
- Compact and self-contained unit available in a bench-top and mobile version.
- Circuit construction is achieved by patching together the desired components.
- All internal components and circuits are terminated as 4mm safety-type terminal sockets.
- Internal circuits are fully protected against overload and short-circuit faults.
TECHNICAL SPECIFICATIONS
- Input: 240/415VAC, 20A, 3 phase, 50Hz.
- Output: 240/415VAC, 20A, 3 phase, 50Hz to be connected to resistive, inductive and capacitive loading units.
EQUIPMENT INCLUDES
POWER FACTOR CORRECTION PANEL EM-60-01-06 | |
![]()
|
o 3 x 22mm Pilot Lamp (R/Y/B) Main Phase Lamp
o 1 x Power Factor Regulator/Controller 6 steps o 6 x Capacitor Banks of assorted ratings from 1 to 5KVAr o 1 x Circuit Breaker 32A TP o 6 x Circuit Breaker 16A TP o 6 x Magnetic Contactors 240V o 1 x Power Factor Meter 3 Phase o 6 x Indicating lights 240V o 1 x 32/5A Class 3, 5VA C/T Coil |
THREE PHASE POWER QUALITY METER EM-30-13-16 | |
![]() o o Modular design o Display Type: HD LCD Display o Real-Time Measurement · Phase voltage: V1, V2, V3, Vlnavg Line voltage: V12, V23, V31, Vllavg Current: I1, I2, I3, Iavg, In Active power: per phase and total active power Reactive power: per phase and total reactive power Apparent power: per phase and total apparent power Power factor: per phase and total power factor Total frequency o Energy And Demand · Four quadrant active energy: Import, Export, Total, Net Four quadrant reactive energy: Import, Export, Total, Net Active, Reactive, Apparent demand
|
o Power Quality Analysis
· Voltage unbalance Current unbalance Voltage THD (Total harmonic distortion), Odd-even harmonic distortion Voltage individual harmonics, Crest factor Current THD, Odd-even harmonic distortion Current individual harmonics, K factor o Communication · Ethernet 10/100M network port · RS485 communication port · MODBUS RTU communication protocol o Trend Logging · Phase voltage Line voltage Current Active power Reactive power Apparent power Power factor Frequency Three-phase unbalance Active energy Reactive energy Apparent energy Phase o Settable Logging Interval · Logging from 1min to 60min, interval settable o Software Accessibility · 4 Tariffs (DataLog) Sharp, peak, flat, valley in different season and schedule (TOU) o PowerMeter Management Software Interface o Accuracy: ±0.5% o Protection: Fuse o Power Supply: AC240VAC, 50Hz o Terminals: 4mm Safety Socket o Unit Type : Panel H2 |
POWER MANAGEMENT SOFTWARE
EM-30-13-16-PMS |
RESISTIVE LOAD UNIT
EM-30-07-01 |
![]() o PC management software; web browse data o True-RMS measuring parameters o ANSI and IEC 0.2 accuracy class o Power quality analysis o 4 quadrant energy o Data logging o Measure individual harmonics from 2nd to 49th o TOU, 4 Tariffs, 6 Seasons, 6 Schedule
|
![]() Single-Three phase Resistive Load 7 steps variable per phase o Max Power: 3 X 2000Watt o Voltage: 240/415 Volt o – Unit Type: Top Table Main Characteristics
|
INDUCTIVE LOAD UNIT EM-30-07-02 | CAPACITIVE LOAD UNIT EM-30-07-03 |
![]() Single-Three phase Inductive Load 7 steps variable per phase o Max Power: 3 X 2000VA o Voltage: 240/415 Volt o – Unit Type: Top Table Main Characteristics
|
![]() Single-Three phase Resistive Load 7 steps variable per phase o Max Power: 3 X 2000VA o Voltage: 240/415 Volt o – Unit Type: Top Table Main Characteristics
|
4MM SAFETY STACKABLE TEST LEAD SET EM-30-15-01 | |
![]()
|
o The set consists of 50 leads in 5 different coded colors (Red, Yellow, Blue, Black and Green) and lengths chosen to allow the realization of all experiment manual.
o Leads are capable of 15A current safety plugs. o Safety Terminal Plug : 4mm · 250mm x 15 units · 500mm x 15 units · 1500mmcm x 15 units o 19mm Bridging Plug Set x 10 units o 19mm Bridging Plug Set (Stackable) x 10 units |
EXPERIMENTAL TABLE
EM-30-16-01-02 |
EXPERIMENT PANEL FRAME
EM-30-16-02-02 |
![]() o 5′ Standard Desktop o Dimension: · Length : 1500mm · Width : 800mm · Height : 850mm
|
![]() o Din Standard A4 With Two Shelves o Side Frame: T Shape o Dimension: · Length : 1450mm · Width : 20mm · Height : 300mm |
MANUAL AND BROCHURES
- Schematic Diagram
- Instruction and Experiment manual
Note: Due to products continuous development process, layout and specification may change without prior notices.