Description

This series of Inductive Loads is designed to be used with all AC/DC Generators, Machines and Three Phase Transformer in a training environment. For this purpose the units are enclosed in metal housings and provided with Educational Terminal Boards with 4 mm safety terminals socket and clear synoptic showing the feasible connections. The units are also provided with a reference manual which illustrates their use and typical experiments.

Single-Three phase Inductive Load 7 steps variable per phase

Max Power     : 3×100 VAR

Voltage          : 240/415 Volt

Frequency     : 50Hz

Protection      : Fuse

 

MAIN CHARACTERISTICS

  • Can be connected in Series, Parallel, Star and Delta configurations.
  • Can be connected to AC Single and 3 Phase sources.
  • Controlled by 3 x 3 circuit breaker switches for 7 steps selection.

 

TESTING DATA TABLE

At Voltage 240 Volt / Phase, 300 VARs (Max Power 3 x 100 VARs)

 

No Positions Inductance (H) S1 Inductance (H) S2 Inductance (H) S3 Power Absorbed (VARS)
  SW1 SW2 SW3        
0 OFF OFF OFF      
1 OFF OFF ON 12.65 12.38 12.46 18.30
2 OFF ON OFF 5.59 5.43 5.71 36.70
3 OFF ON ON 3.86 3.76 3.90 55.00
4 ON OFF OFF 3.11 3.18 3.19 73.30
5 ON OFF ON 2.49 2.62 2.54 91.70
6 ON ON OFF 1.98 2.05 2.03 110.00
7 ON ON ON 1.71 1.75 1.74 128.40
 
No Positions Current (A) S1 Current (A) S2 Current (A) S3 Power Absorbed (VARS)
  SW1 SW2 SW3        
0 OFF OFF OFF      
1 OFF OFF ON 0.06 0.06 0.06 18.30
2 OFF ON OFF 0.10 0.09 0.09 36.70
3 OFF ON ON 0.16 0.16 0.15 55.00
4 ON OFF OFF 0.22 0.18 0.18 73.30
5 ON OFF ON 0.27 0.24 0.25 91.70
6 ON ON OFF 0.32 0.28 0.26 110.00
7 ON ON ON 0.38 0.34 0.35 128.40

 

EXPERIMENTS COVER

 

EXPERIMENT 1: BALANCED THREE-PHASE LOADS

Experiment 1.1: Star connection with balance resistive load

Experiment 1.2: Delta connection with balance resistive load

 

EXPERIMENT 2: UNBALANCED THREE-PHASE LOADS

Experiment 2.1: Star connection with unbalance three-wire resistive load

Experiment 2.2: Star connection with unbalance four-wire resistive load

Experiment 2.3: Delta connection with unbalance resistive load

 

EXPERIMENT 3: BALANCED THREE-PHASE RL LOADS

Experiment 3.1: Star-Connected with series R-L Load

Experiment 3.2: Delta-Connected with series R-L Load

 

EXPERIMENT 4: BALANCED THREE-PHASE RC LOADS

Experiment 4.1: Star-Connected with series R-C Load

Experiment 4.2: Delta-Connected with series R-C Load

 

EXPERIMENT 5: BALANCED THREE-PHASE RLC (SERIES) LOADS

Experiment 5.1: Star-Connected with series R-L-C Load

Experiment 5.2: Delta-Connected with series R-L-C Load

 

EXPERIMENT 6: BALANCED THREE-PHASE RLC (PARALLEL) LOADS

Experiment 6.1: Star-Connected with parallel R-L-C Load

Experiment 6.2: Delta-Connected with parallel R-L-C Load

 

 