Electrical Wiring Installation Trainer EM-58503
Description

The system deals with standard installation circuits for all general service lamps and fluorescent lamps in conjunction with our training panel system. This requires no tools so the trainee can concentrate entirely on putting his accrued knowledge into practice. Particular emphasis is placed on adherence to the applicable regulations governing electrical installations.

Safety sockets and Test Lead Set guarantee optimal low-voltage range protection against personal injury during the experiments.

Due to the vertical arrangement of the experimental panels, the experimental set-up can be seen from a far distance and can he adapted step by step to the course of the lessons or lectures.

The experiments permit practice-oriented, hands-on training to be carried out, thus assuring the trainees of the proficiency needed to handle the tasks and the equipment found in this field. The training panels and functional units with block circuit diagrams and signal diagrams permit clear and understandable assembly of the experiment circuits. Beginning with the basic circuits, the student proceeds to tackle more complex circuits in electrical system using a proven step-by-step method designed for didactic results. And of course, the model behind the entire system is the circuitry used in industrial applications.

Request A Quotation

Description

Experiments cover the following topics:

  1. Single phase AC circuits
  2. Various Lamp And Appliances Circuits
  3. Standard Installation Circuits
  4. Switches And Push Buttons Circuit
  5. Fluorescent Lamps Circuits
  6. Staircase Lighting circuits and Time-Delay Switching
  7. Typical electrical signal is observed and measurement

 

SINGLE PHASE POWER SUPPLY MODULE

EM-10-09-02

CURRENT FLOW MODULE

EM-10-04-02

 

EM-10-09-02-P2

·        Modular Design

·        Power Input: 1 Phase 240V, 13A, 50Hz via input 3 pin power cord UK Type.

·        Protection: Earth leakage circuit breaker and miniature circuit breaker

·        Complete with START and STOP Push Button

·        Unit Type : Panel H1

·        Terminals: 4mm Safety Sockets (Color Coded)

EM-10-04-02-P2

Input: 240VAC, 50Hz 1-Phase

 

 

 

 

 

ON/OFF SWITCH (SINGLE POLE)

EM-10-06-01

CHANGE-OVER SWITCH (LEFT)

EM-10-06-02

EM-10-06-01-P2

Input: 240VAC, 50Hz 1-Phase

Single Pole 1 Gang

Switch type: Disconnecting switch

EM-10-06-02-P2

Input: 240VAC, 50Hz 1-Phase

Switch type: Two-way Switch

 

MULTIPLE SWITCH

EM-10-06-03

PUSH BUTTON SWITCH

EM-10-06-05

EM-10-06-03-P2

Input: 240VAC, 50Hz 1-Phase

Switch type: Two-circuit Switch

EM-10-06-05-P2

Input: 240VAC, 50Hz 1-Phase

Switch type: Push button Switch

CROSS-OVER SWITCH

EM-10-06-06

CHANGE-OVER SWITCH (RIGHT)

EM-10-06-07

EM-10-06-06-P2

Input: 240VAC, 50Hz 1-Phase

Switch type: Intermediate switch

  EM-10-06-07-P2

Input: 240VAC, 50Hz 1-Phase

Switch type: Two-way Switch

SOCKET OUTLET

EM-10-06-09

DIMMER

EM-10-05-08

EM-10-06-09-P2

Socket Outlet

Input: 240VAC, 50Hz 1-Phase

Operation: Voltage connector with ground

EM-10-05-08-P2

Input: 240VAC, 50Hz 1-Phase

 

ANALOG TIMER SWITCH

EM-10-07-04

STAIRCASE LIGHTING TIME-DELAY SWITCH

EM-10-07-06

EM-10-07-04-P2

Input: 240VAC, 50Hz 1-Phase

 

 

EM-10-07-06-P2

Input: 240VAC, 50Hz 1-Phase

Automatic Staircase Relay 240vac

Relay coil: 240VAC

LOAD BULB MODULE

EM-10-10-02

LED DOWNLIGHT

EM-10-10-03

EM-10-10-02-P2

Input: 240VAC, 50Hz 1-Phase

Load Bulb, AC 240V, 50Hz 1-Phase X 4 Unit

EM-10-10-03-P2

Input: 240VAC, 50Hz 1-Phase

LED Light AC 240V, 50Hz 1-Phase

HALOGEN DOWNLIGHT

EM-10-10-04

INCANDESCENT LAMP

EM-10-10-05

EM-10-10-04-P2

Input: 240VAC, 50Hz 1-Phase

 

EM-10-10-05-P2

Input: 240VAC, 50Hz 1-Phase

Lamp type: Incandescent

COMPACT FLUORESCENT LAMP

EM-10-10-06

FLUORESCENT LAMP HOLDER (LEFT)

EM-10-10-07

EM-10-10-06-P2

Input: 240VAC, 50Hz 1-Phase

Lamp type: Compact Florescent With Ballast

EM-10-10-07-P2

Input: 240VAC, 50Hz 1-Phase

 

FLUORESCENT LAMP STARTER & CAPACITOR

EM-10-10-08

MAGNETIC BALLAST

EM-10-10-09

EM-10-10-08-P2

Input: 240VAC, 50Hz 1-Phase

Nominal Capacitance: 4μF & 2μF

EM-10-10-09-P2

Input: 240VAC, 50Hz 1-Phase

 

ELECTRONIC BALLAST

EM-10-10-10

FLUORESCENT LAMP HOLDER (RIGHT)

EM-10-10-11

EM-10-10-10-P2

Input: 240VAC, 50Hz 1-Phase

EM-10-10-11-P2

Input: 240VAC, 50Hz 1-Phase

FLUORESCENT LAMP BULB

EM-10-10-12

SINGLE PHASE POWER ANALYSIS METER

EM-30-13-14

EM-10-10-12-p2

Input: 240VAC, 50Hz 1-Phase

 

 

EM-30-13-14-P2

Input: 240VAC, 50Hz 1-Phase

Display Type: Digital LED Display

Measuring Function: Voltage V, Current A,

Active Power KWH, Reactive Power VAR,

Appearant Power VA, Power Factor PF

Measuring Range : Voltage : 0 ~ 250V

Current : 0 ~ 5A

SINGLE PHASE KILOWATT HOUR METER

EM-30-13-18

4mm SAFETY STACKABLE TEST LEADS SET & 19MM LINK SET EM-10-10-11
EM-30-13-18-P2

Input: 240VAC, 50Hz 1-Phase

Type: Moving coil

Speed: 1200 Turns/1kw/Hour

Voltage coil: 240 VAC

Current coil: 5A/15A

Accuracy: Class 1.5

EM-21-12-01-P1

Leads are capable of 10A current safety plugs.

Safety Terminal Socket : 4mm

Length: 25cm, 50cm & 100cm

Color: Red, Yellow, Blue, Black & Green

 

 

EXPERIMENTAL TABLE

EM-30-16-01-02

EXPERIMENT PANEL FRAME

EM-30-16-02-02

EM-30-16-01-01-3D-P1

5′ Standard Desktop

Dimension:

Length : 1500mm

Width : 800mm

Height : 850mm

3 Layer Drawer (Optional)

 

 

EM-30-16-02-P1

Din Standard A4 With Two Shelves

Side Frame: T Shape

Dimension:

Length : 1450mm

Width : 20mm

Height : 300mm

 

MANUAL

  1. Manuals written in English that cover introduction to the system, operational procedures and experiments procedures provided.
  2. Softcopy & hardcopy of Lab sheet for all experiments.

 

Note: Layout and specification may change without prior notices for products continuous development and improvement process.