Product properties:

  • Graphic display of the stored temperature values
    • Interactive display, user-scalable
    • Display of limit violations
    • Freely selectable line color
  • Monitor temperatures and curves with your browser
    • HTML page design user-variable
    • Direct access to current temperature value, e.g., for integration into other Web pages
  • SNMP temperature polling /Alarm traps for incorporating into your existing SNMP management system
  • E-mail for alarm or reporting functions
  • Adapters:
    • 10/100MBit
    • NTC probe included, PT100 probe can be connected
  • Plug-and-play:
    • Attach temperature probe
    • Assign IP number
    • Connect Web-Graph 1x Thermometer to the network
    • That's it!

Technical data:

Temperature sensors: NTC and PT100 connection
Network: 10/100BaseT autosensing
Supply voltage: 12-24V AC / DC using screw terminal
Measuring unit
Sensor: NTC 10k, PT100-connection, 2-,3- or 4-wire
Measuring range: -45°C...105°C (PT100)
-45°C...75°C (NTC)
Resolution: 1/10°C
Measuring error: ±0.3°C, ±5% (NTC) ±0.3°C, ±2% (PT100)
Polling frequency: 1, 5, 15, 60 min
Memory depth (64k): min. 14 weeks, max. 16 years
Deviation of the internal clock: max. 4.32 min. / month
Other data
Electrical isolation: Signal inputs to network: min. 500 volts
E-mail function: Mail for sending alarms or as reporting function
Supply voltage: DC 12V (-5%) - 34V (+5%)
AC 9Veff (-5%) - 24Veff (+5%)
DC 48V (+10%) on request
Current consumption: AVG: 200mA @12VDC, 100mA @24VDC, 100mA @20VAC
Max: 240mA @12VDC
Power supply:

Supplied power adapter
or 12..24 V DC/AC

Configuration interface: RS232 serial port, 9600 baud, 8 data bits, 1 stop bit, no parity
Housing: Plastic compact housing, 105x75x22mm
Weight: approx. 200g
Ambient storage temperature: -40..+70°C
Ambient operating temperature: 0 .. +60°C
Included:

1x Web-Graph 1x Thermometer for top-hat rail mount
1x NTC thermocouple
1x AC adapter

 

Web-IO 2x/8x Thermometer

 
 
Temperature monitoring from a browser, SNMP, e-Mail, UDP

All settings made using Web Based Management



Start page

Value list

Your own page

Web Based
Management


e-Mail


Alarms

XML Config.

Time Server

Diagnostics


 Web-IO 8x Thermometer


Product characteristics:

  • Output functions
    • Direct access to current measured values and value archive via browser
    • Java applet for integration in your own Web pages
    • Targeted temperature polling for integration in any application
    • Excel download for post-processing the measured values
    • SNMP polling of the measured values
    • Modbus polling of the measure values (optional, please inquire)
  • e-Mail generator
    • for alarms when limits are exceeded
    • Configuration with various technologies
  • for cyclical reports
    • via browser with selection tree, password protection for a complete configuration session, default restore option
    • XML down- and upload for independent archiving and series configuration
    • SNMP
  • Connections:
    • 10/100 BaseT Ethernet
    • 8 signal inputs, optional NTC, PT-100 2- or 4-wire
    • One NTC temperature sensor included
  • Plug-and-Play:
    • Install temperature sensor
    • Assign IP number
    • Connect Web-IO 2x, 8x Thermometer to the network
    • That's it!
Technical Specifications:

 
 
 

Main selection criteria:

Web-IO 2x Thermometer
Web-IO 8x Thermometer
Temperature sensors:

NTC and PT100 terminal
Network:
10/100BaseT
autosensing
Supply voltage:
12-24V AC / DC with screw terminals

Price:

RM3,200.00

RM3,800.00

Measuring unit:
max. number of sensors:
2
8
Temperature sensors:
NTC 10k, PT100 connection, 2-, 3- or 4-conductor
Measuring range:
-45°C...75°C
Resolution:
1/10 °C
Temperature sensors:
±0.3°C, ±5% (NTC) ±0.3°C, ±2% (PT100)
Memory frequency:
1, 5, 15, 60 min
Memory depth:
min. 14 days, max. 16 weeks
min. 8 weeks, max. 16 weeks
Deviation of the internal clock:
max. 4.32 min. / month

Other data:

Galvanic isolation:

Signal inputs to network: min. 500 volts

E-mail function:
Mail for sending alarms or as reporting function
Supply voltage:
DC 12V (-5%) - 34V (+5%)
AC 9Veff (-5%) - 24Veff (+5%)
Current draw:
120mA, typ. 85mA @24VDC

Emergency access:

RS232 serial port, 9600 baud, 8 data bits, 1 stop bit, no parity

Housing:
Plastic compact housing, 106.8 x 87.8 x 62.6 (l x w x h)
Weight:
approx. 200g
Ambient storage temperature:
-40..+70°C
Ambient operating temperature:
0 .. +60°C
Included:
Plug-in power supply, 1x NTC sensor with 1m cable included