Digital Clamp-on Meter Selection Guide

 

SELECTION GUIDE

Features

SDC91

SDC93

SDC95

SDC96

SDC290

SDC90A

/90AT

SDC70

SDC75

SDC200

SDC210T

Max Display Counts

4000

4000

4000

3260

4000

4000

2000

4000

4000

4000

Auto/Manual

 M

A

A

A

A

M

M

A

M

M

True RMS

 

 O

O

O

 

 

 

 

 

 

Data Hold

O

O

O

O

O

O

O

O

O

O

Analog Bar Graph

 

O

O

O

O

 

 

 

 

 

Frequency

 

O

O

O

O

 

O

 

 

 

Trim Mode(smoth)

 

O

O

O

O

 

 

 

 

 

Continuity

O

O

O

O

O

O

O

O

O

O

Peak HOld & Reading

H

R

R

R

-

O

O

O

O

O

Record(Min/Maz)

 

 

O

O

O

 

 

 

 

 

HDR MODE

 

 

 

O

 

 

 

 

 

 

AC/DC Amps

 

O

O

O

O

 

 

O

O

O

Auto Power Off

 

O

O

O

O

 

 

O

 

 

Zero Adjust(DC A)

O

O

O

O

O

O

O

O

O

O

Low Battery Indicator

O

O

O

O

O

O

O

O

O

O

Overrange Indicator

O

O

O

O

O

O

O

O

O

O

Temp. Measures

 

 

 

 

O

O(90AT)

 

 

 

 

Jaw Capacity

 2 "

Harmonic distorion

O

O

O

O

O

O

O

O

O

O

Carrying Case

O

O

O

O

O

O

O

O

O

O

CUL Listed

 

 

 

O

O

 

 

 

 

 

SDC290 / SDC91 / SDC93 / SDC95 / SDC96

*. Safety Standards : UL3111, CUL, CAT. III locations IEC1010-1 for use in 600V

*. Jaw Capacity : 1.5 inch

*. Analog Bar Graph (except SDC91)

*. Auto Range (except SDC91)

*. Continuity Buzzer

*. Trim Mode (smooth) : SDC93, 96, 95

*. CUL Listed (SDC290, 296) File No. E188344


SDC70 / SDC75

*. Meets IEC Standards

*. Frequency Measurement Capability (SDC70)

*. Protective hand guard to prevent on accidental contact with conductor

SDC90A / SDC90AT

*. Easy to read Display

*. Data Hold

*. Low Battery Indicator

*. Measures up to 1000A Ac

*. continuity Buzzer

*. Peak Hold

*. Over range Indicator

*. Temperature Measures(90AT Only)

SDC200 / SDC200T

*. Overload Protection on all Functions and ranges

*. Peak Hold

*. Temperature Range (SDC200T Only)

*. Continuity Buzzer

*. Data Hold

*. AC/DC Amp

*. Zero Adjust (DC A)

*. Low Battery Indicator

*. Over range Indicator


SPECIFICATION

 

 

SDC91

SDC93

SDC95

SDC96 (*HDR)

 

DCV

4V

400V

 

±0'75% ± 3

40,400, 600V             ±0.75% ±3

 

N/A

400A ±2% ± 10

700A ±2% ± 10

 

DCA

N/A

 

 

ACV

(45 to 60Hz)

400V

600V

±1.2% ± 3

40, 400, 600V         ±1.0% - 3

 

ACA

40A

400A

700A

±1.5% ±5

40A   ±2%  ±20(45Hz to 65Hz)

400A  ±2 % ±10(45Hz to 65Hz)

700A  ±5%  ±10(45Hz to 65Hz)

 

OHM

4KΩ

±l % ± 3

.

400Ω ±1% ±10

4K, 40KΩ ±1% ±3

 

Continuity

3V  <110Ω

 

3V  <100Ω

 

Diode

-

 

3V Approx. 2.5mA

 

 

Frequency

-

1KHz ±0.2% ±2

       10KHz

 

SDC290

 

SDC90A

 

SDC200T

SDC210

DCV

400mV

4V

40V

400V

600V

±0.75%±3

400mV

4V

400V

 

 

 ±0.8% ±1

 

 

400V

600V

 

 ±0.8% ±1

 

DCA

N/A

N/A

400A

1000A

  ±1.5% ±3

ACV

(45to450Hz)

4V

40V

400V

600V

 ±1.2% ±3

 

400V

650V

 

 

±1.2% ±4

 

400V

600V

±1.2%±4

ACA

40A

400A 700A

±1.5% ±5

 40A

400A

1000A

±1.5% ±4

 40A

1000A

 

±1.5% ±4

OHM

400Ω

4kΩ

40 KΩ

400kΩ

 

±1.5%±5

400kΩ

40 KΩ

 

±1%±2

40 KΩ

 

±1%±1

4MΩ

±1.5%±3

40MΩ

±1%±3

Temp

(Best Accuracy)

-40 to 2372°F

 ±3°F + 5

N/A

-40 to1200°F

±1% ±2°F

N/A

Capacitance

1μF

10μF

100μF 1000μF

10000μF

 

±1.2%±5

 

±3%±5

N/A

N/A

Continuity

3V    <100Ω

3V     <100Ω

3V    <100Ω

Diode

N/A

N/A

N/A

Frequency

1 KHz 

10 KHz

±0.2% ±3

N/A

N/A

Measure

SDC70

SDC75

DCV

200V

±0.5% ±2

4V

40V

400V

600V

±0.5% ±2

ACV

200V

600V

±1.0% ±5

4V

40V

400V

       600V

 

 

 ±1.0% ±5 (45 – 450Hz)

 

DCA

N/A

400A

1000A

±1.5% ±5

    ±2% ±10

ACA

400A

1000A

±1.5% ±5

     ±2% ±5

400A

1000A

    ±2% ±5

    ±2.5% ±10

OHM

2KΩ

±1.2% ±3

 

400Ω

4KΩ

40KΩ

400KΩ

±0.75.0% ±5

4MΩ

40MΩ

  ±1.5.0%±10

Frequency

2 KHz

20 KHz

200 KHz

2MHz

 

±0.5% ±3

N/A

 

 

 

 

 

10MHz

±1.0% ±3

Continuity

< 30Ω

 